Cape Water Tech
For Iron Precipitation in Water Treatment Systems
Based on your flow rate of 40 L/min and 11 ppm iron, we recommend an ozone generator with an output between 15-20 grams per hour. This provides adequate safety margin for complete iron oxidation.
1. Convert flow to m³/h: 40 L/min × 60 ÷ 1000 = 2.4 m³/h
2. Ozone dosage needed: 11 ppm × 0.43 = 4.73 ppm (g/m³)
3. Base ozone required: 2.4 m³/h × 4.73 g/m³ = 11.4 g/h
4. With safety factor (1.5): 11.4 × 1.5 = 17.1 g/h
*Ozone demand factor of 0.43 mg ozone per mg iron is based on standard oxidation stoichiometry